» Support » Downloads » Release Builds (64 bit)
InspectionWare Release Build: Version 12.512.0 (64 bit)



Latest Release Notes

New Features:

(1) Added Recreate Archive File task to Workspace Archive, which writes a new archive file on the server when the one there is missing or cannot be read, so that the workspace can be checked out again.

(2) Collapsable Grouped Controls can now have multiple buttons/controls as the header.

(3) Added Grid Control.Accept Returns: Shift + Enter starts a new line in a text cell, and a cell with several lines copies and pastes to and from Excel as one cell.

(4) Added an In Source choice to UT Beam Set.Probe Configuration Location, which uses the probe configuration of the nearest beam set towards the source of the data, through linked sources such as an Aggregate Data.

Bug Fixes:

(1) Fixed Contour Axis.Go To Contour() ignoring T Position when Goto Closest S Position is False, and going to the start of the contour instead of the nearest point when only Goto Closest S Position is True.

(2) Fixed InspectionWare taking minutes to close, or to close a workspace, when many temporary files of C Sharp Compiler nodes had built up, such as those left by copies that had crashed. They are now deleted in the background.

(3) Fixed Workspace Archive.Override Checkout Status(), Workspace Archive.Heal UUID Integrity() and Workspace Archive.Revert To Previous Version() saving an archive that had not been read from the server, which reset Workspace Archive.Workspace ID and Workspace Archive.Description there. They now read the archive first and stop when it cannot be read.

(4) Fixed ZMQ Msg Router not connecting when ZMQ Msg Router.Is Enabled was turned on, which left the MCP Server unreachable after switching from the Named Pipe Msg Router back to the ZMQ Msg Router.

(5) Fixed a Duet Channel whose UT Beam Set has UT Beam Set.Matrix Capture turned on, or UT Beam Set.Sweep Type set to Full Matrix Capture Pitch Catch, being set up on the instrument for summed A-scans while its data was sized for one A-scan per receive element.

(6) Fixed a ZMQ Msg Router whose ZMQ Msg Router.Socket Type is Router, such as the MCP Server's, no longer answering any request after a client sent it a message with an extra part, as a Request socket does.

(7) Fixed a request received through the MCP Server being carried out in the middle of a C Sharp Compiler compile, which crashed InspectionWare when the request deleted that C Sharp Compiler. Such requests now wait until the compile has finished.

(8) Fixed a stashed workspace, such as one loaded by Workspaces Tools.Stash Previous Version(), being compiled and executed in the background, which could crash InspectionWare when another workspace was stashed.

(9) Fixed an AOS Waveform Channel whose UT Beam Set.Sweep Type is Full Matrix Capture Pitch Catch being downloaded as a phased array sweep instead of a full matrix capture.

(10) Fixed an Electronic Gearing with Activate Only During Motion turned off switching off Electronic Gearing.Slaves Linked every time its workspace loaded.

(11) Fixed requests sent to the MCP Server through the ZMQ stdio bridge (ZMQStdioBridge.exe) being delayed by seconds or minutes while InspectionWare was idle.

(12) Fixed setting a property of a Workspace Archive, such as Workspace Archive.Exclude From Testing or Workspace Archive.Description, overwriting the rest of the archive's record on the server, which reset Workspace Archive.Workspace ID and cleared another user's check-out when the archive had not been selected since InspectionWare started, or had changed on the server since it was selected.

(13) Fixed test results reporting that a test increased process memory by an enormous amount, such as 18014398509478996 KB, when the process actually finished with less memory than it started with.

(14) Fixed a workspace that was checked out being recorded as checked in on the server after its Workspace Archive failed to read the archive file there, such as when the server could not be reached for a moment.

(15) Fixed Main Window.Check In Workspace(), Workspace Archive.Check In() and Workspace Archive.Undo Check Out() undoing a change that another computer had saved to the Workspace Archive since this computer last read it, such as to Workspace Archive.Exclude From Testing or Workspace Archive.Product.

(16) Fixed Version Control.Check Out() and Workspace Archive.Check Out() making the workspace writable and moving it to its next version when the check-out could not be recorded on the server. A message now says why, and the workspace stays read-only.

(17) Fixed a child instance of InspectionWare replacing the computer's list of Workspace Libraries with its own when a library was mapped in it, or Workspace Archive.Local Path was set in it. A child instance starts without the libraries, so the list was left holding only what had been mapped there.

(18) Fixed a Waveform Channel whose UT Beam Set has UT Beam Set.Matrix Capture turned on collecting one sample more than its A-scan window when that window is an odd number of samples long.

(19) Fixed a Check Box, Ribbon Check Box or Radio Button taking a second click while its On Control Event with On Control Event.Execute On set to Property Set was still running, which set the property again without running the event and logged that execution was recursive. The click is now ignored until the event has finished, unless the new Check Box.Can Be Set During Its Event is turned on, in which case the click sets the property and the event is not started again.

(20) Fixed a crash in UT Beam Set.Simple Linear Escan() when Element Step X or Element Step Y was zero.

(21) Fixed a possible crash in Structured File.Export() and Structured File.Import() when the file is transferred through a message gateway.

(22) Fixed Collection Info.Load Into Manager() copying the properties of the node a Find Nodes had found when the scan stored its information over the node that Find Nodes has found now, and giving the Find Nodes its own copy of that node when Loading Mode is Import Structure.

(23) Fixed InspectionWare closing when Grid Control.Paste() put text into a check box column with Grid Control.Paste Mismatch Handling set to Apply Changes.

(24) Fixed a copy of a Find Nodes owning a copy of every node it had found, which Find Nodes.Clear() did not remove and Find Nodes.Number Of Nodes counted. A copy now has no found nodes until it finds again.

(25) Fixed a copy of an FMC To PWI, Sparse FMC, FMC Recovery or FMC ROI Trim, such as one made by Processor Package.Update From Package(), using a copy of the source's Probe Configuration taken when the node was copied, so that later changes to the probe were not followed.

(26) Fixed a copy that includes a Find Nodes, such as one made by Processor Package.Update From Package(), moving the connections its other nodes have to a node the Find Nodes had found, for example the target of an Execute Task or the source of an Aggregate Data, to a copy of that node or to another node of the same name.

(27) Fixed setting Total Focuser.Reconstructed Gain on a Total Focuser that shares another's travel time maps logging "Travel time map has no GPU context" on its own Element Travel Time Map and Beam Travel Time Map.

(28) Fixed Ctrl + V in a Grid Control moving the cells that follow an empty clipboard cell into the wrong columns: each clipboard cell is now pasted at its own row and column, and an empty one leaves the grid cell unchanged.



Overview

This document contains a downloadable Windows installer for InspectionWare as well as the release notes covering the current version.

Software requirements

  • Operating system: Windows 10 or 11. The latest Windows updates must be installed.
  • InspectionWare 12 ships as a 64-bit application. 32-bit builds are produced only occasionally.
  • .NET Framework 4.8 or later is required. If it is not already installed, click here to download and install it.

Hardware requirements
  • CPU: A processor supporting the AVX2 instruction set is required. This includes 2013-or-later Intel processors and 2015-or-later AMD processors. (List of supported CPUs.) InspectionWare will not install or run on a CPU without AVX2.
  • GPU (optional, for accelerated processing): InspectionWare provides two GPU acceleration backends:
    • DirectX — any GPU supporting DirectX 11 (feature level 11_0) or later, from AMD, Intel, or NVIDIA. A CPU-based software fallback (WARP) is also available when no compatible GPU is present.
    • CUDA — an NVIDIA GPU with architecture ≥ Turing (e.g. RTX 2060, Quadro RTX, T4) and NVIDIA driver ≥ 576.02. NVIDIA GPUs older than Turing (e.g. Pascal / GTX 10-series) are not supported by the CUDA backend.

Additional resources

After downloading the installation files you may also want to review/download the following resources: Download and Installation Instructions
  1. Right-click on the file name in the "Downloads" section below and choose "Save Target As" or "Save..." to download the file to your computer.
  2. Locate the file you have just downloaded then run it to initiate the install process.



Access to downloads on this page is restricted.
Please provide the following:
( Required field)
E-mail:
Download Password:
The following file links will become active once the required information is submitted:
Downloads
InstallInspectionWare64 12.512.0.exe (133.7 MB)
Release Notes.txt (187.4 kB)
Document Reference
Categories
NDE Software
InspectionWare 
Product Version/Model
12.512.0 
Document Number
WEBB-DYTVPR3709
Published
10/13/2026 Rev: 1.0
  Print Email page Share