» Support » Downloads » Release Builds (64 bit)
InspectionWare Release Build: Version 12.508.0 (64 bit)



Latest Release Notes

New Features:

(1) Grid controls with Row Labels set to Use First Column now show the first column's name in the row header box above the row labels.

(2) Added Diagnostics Should Log.

(3) Hovering over applicable Wedge and Wedge Builder properties displays a tooltip with an image.

(4) Weld Profile Builder sends Segment Names to Weld Profile, depending on the Weld type.

(5) Weld Profile can now hold Segment Names for its Weld.

(6) The temporary files the C Sharp Compiler generates are now deleted when the workspace is closed and when InspectionWare exits, instead of building up in the installation's Temp folder.

(7) Added Build Property Map task to Annotation Set and Indications Data Annotations, which fills the Property Map from one dialog with a combo of the source table columns for each annotation property.

(8) Added Grid Control.Paste Mismatch Handling, which chooses whether pasting data that does not fit the table, such as text in a number column or more columns than the table has, warns first, skips the differences, or changes the table without asking.

(9) Added Merge Indications Data.Count Column, which names a column that will hold the number of source indications merged into each row.

Bug Fixes:

(1) Fixed a scan or sequence occasionally stalling with posted messages waiting after the Message Handler's wake-up message was lost. The handler now re-posts the wake-up when messages have waited without one, and reports how often in the new Message Handler.Wake Up Repost Count property.

(2) Fixed FMC ROI Trim keeping stale windows after its linked Total Focuser is recompiled.

(3) Fixed FMC To PWI producing a different image when executed from a sequence than when executed directly, and drifting on every re-execute.

(4) Fixed Generic Total Focuser silently reading its map from the wrong places when the map's element count differs from the probe's.

(5) Fixed Sparse FMC feeding shifted A-scans to the focuser when the source capture does not hold every requested element pair.

(6) Fixed TFM Point Source Map.Sum On Amplitude writing to an integer row, Aliasing Finder 2D always failing to compile, and Aliasing Mapper 2D rejecting every valid output.

(7) Fixed Total Focuser reconstructions of more than 6144 A-scans failing to launch on CUDA.

(8) Fixed Total Focuser.Calibrate Velocity() sweeping the velocity of the obsolete Inspection Mode instead of the outputs' Tx Mode, writing to a different probe configuration than the maps use, and overwriting an anisotropic velocity table with one number.

(9) Fixed Total Focuser.Mask Geometry Echoes blanking lateral columns at multiples of the wall thickness instead of the backwall depth bands.

(10) Fixed an imported beam-indexed Travel Time Map never being selected by the Total Focuser.

(11) Fixed a raster scan being saved as a Paintbrush NDE file, with its beams declared as a second V coordinate instead of a Beam dimension, after a Paintbrush file had been opened on the same recorder.

(12) Fixed the installer window opening at the top of the screen instead of centered.

(13) Fixed a leak of drawing resources each time a Page or dialog window was closed.

(14) Fixed clicking a button while a workspace was loading being able to start a second operation inside the load.

(15) Fixed C Sharp Compiler.C Sharp Language Version offering no choices to pick from.

(16) Fixed the Element Travel Time Map giving different results when GPU.Backend is DirectX than when it is CUDA, and sometimes leaving map points undefined.

(17) Set Annotation Type no longer adds a stray Indic Prop | Ann Prop column to the Property Map; the header is now a proper group row.

(18) Fixed Cluster 1D.Length being zero, instead of one axis resolution, for an indication that covers a single sample, and fixed such an indication being dropped when it fell at the end of the analysed range.

(19) Fixed Cluster Analysis 1D reporting false indications around undefined samples when Cluster Analysis 1D.Threshold Type is Spike or the data is complex.

(20) Fixed the Index Position plane in a saved NDE file being written as a copy of the Scan Position plane.

(21) Fixed Grid Control.Paste() damaging the table when the clipboard did not match it, for example moving values into the wrong column after an empty cell, clearing a column's type instead of converting it, or offering to turn True/False and list columns into text.

(22) Fixed Unsigned Integer columns in Variables tables coming back as signed numbers after the workspace is reloaded, which made Table Should Match report a type mismatch.

(23) Fixed a number written with a comma as its decimal symbol, such as 1,5, being converted to the wrong value when it set a single-precision number.



Overview

This document contains a downloadable Windows installer for InspectionWare as well as the release notes covering the current version.

Software requirements

  • Operating system: Windows 10 or 11. The latest Windows updates must be installed.
  • InspectionWare 12 ships as a 64-bit application. 32-bit builds are produced only occasionally.
  • .NET Framework 4.8 or later is required. If it is not already installed, click here to download and install it.

Hardware requirements
  • CPU: A processor supporting the AVX2 instruction set is required. This includes 2013-or-later Intel processors and 2015-or-later AMD processors. (List of supported CPUs.) InspectionWare will not install or run on a CPU without AVX2.
  • GPU (optional, for accelerated processing): InspectionWare provides two GPU acceleration backends:
    • DirectX — any GPU supporting DirectX 11 (feature level 11_0) or later, from AMD, Intel, or NVIDIA. A CPU-based software fallback (WARP) is also available when no compatible GPU is present.
    • CUDA — an NVIDIA GPU with architecture ≥ Turing (e.g. RTX 2060, Quadro RTX, T4) and NVIDIA driver ≥ 576.02. NVIDIA GPUs older than Turing (e.g. Pascal / GTX 10-series) are not supported by the CUDA backend.

Additional resources

After downloading the installation files you may also want to review/download the following resources: Download and Installation Instructions
  1. Right-click on the file name in the "Downloads" section below and choose "Save Target As" or "Save..." to download the file to your computer.
  2. Locate the file you have just downloaded then run it to initiate the install process.



Access to downloads on this page is restricted.
Please provide the following:
( Required field)
E-mail:
Download Password:
The following file links will become active once the required information is submitted:
Downloads
InstallInspectionWare64 12.508.0.exe (131.1 MB)
Release Notes.txt (155 kB)
Document Reference
Categories
NDE Software
InspectionWare 
Product Version/Model
12.508.0 
Document Number
WEBB-DXYUB52544
Published
09/16/2026 Rev: 1.0
  Print Email page Share