Build Note:

Removed Branch Descriptions from Add Ins due to Workspace Metadata replacing its functionality.

New Features:

(1) Renamed Add In Metadata to Workspace Metadata.

(2) Updated Part Properties parameter set to accept "Pipe" as an alias for "Pipe OD" and clarified documentation for geometry names.

(3) Improved drag-and-drop handling for UT Beam Set objects on phased array rays and raytracer nodes.

(4) Added Reference Coordinates to Simulator Display, which sets the viewpoint up in a Part's coordinates instead of world coordinates.

(5) Simulator Display.View Mode now offers the YZ, ZY, XZ, XNegY and NegXY viewing planes.

(6) Added Platform Testing.Save Results In History, which controls whether a completed Run All Tests adds its failures to the shared Test Results History file on the server. It is off by default.

(7) Added Dummy tasks to Add Ins to create light Dummy copies of an Add In.

(8) Packages now support custom On Add In Loaded and Before Add In Saved tasks.

(9) Added "Before Add In Loaded" and "Before Add In Saved" options to On Add In Event's Execute On property.

(10) Added Execution Tree, a view that runs a node or button while the Performance Analyzer records, and shows the calls it made as a tree with elapsed and self times.

(11) Total Focuser keeps the travel time maps of outputs with different skips on the GPU, and stores 0-skip maps as a single layer when the wall thickness varies, so compiling uses less memory and time. The Element Travel Time Map outputs then show grey in the object tree until the map is dropped onto a plot or the desktop or Element Travel Time Map.Update Display Maps() is run, and they stay filled while a plot shows them.

Bug Fixes:

(1) Fixed Line Plot drawing nothing for 32 bit integer data.

(2) Fixed a bug where the user defined types of a C Sharp Compiler or Load Assembly stayed available after the node was deleted or its workspace closed, so creating one of them failed with a missing assembly error.

(3) Preserved legacy workspace compatibility for Toolbox nodes.

(4) Fixed Offline Data.Configure Build Data Set() losing the index axis, so offline data could not be set up for a scan that has both a scan and an index axis.

(5) Fixed Data Recorder 2D not replaying Offline Data when its Motor Control is External, so a raster scan collected nothing.

(6) Fixed Offline Data replayed into a raster scan landing in the wrong cells, with every scan line written to the first index position and the first position on each axis left empty.

(7) Fixed a crash when closing InspectionWare after running a test suite.

(8) Fixed each index line of an offline raster scan losing its first sample, so alternate ends of every line were left empty.

(9) Fixed Indications Table.Add Column() ignoring its Value parameter and filling the new column with the column name.

(10) Fixed a memory leak where primitives built by a Part from a parameter set were never freed.

(11) Fixed scans reporting "!!! Scan starting while motors moving" when an externally controlled axis was already moving, such as the scan axis when Data Recorder 2D.Motor Control is Internal Index/ External Scan.

(12) Fixed individual Add In save not saving in the correct subfolder.

(13) Parts now show all contained Primitives.

(14) Fixed ES Beam Tool.Copy To Probe Configuration() doing nothing while still reporting success. It now copies the chosen Probe into the target Probe Configuration without renaming it, and reports an error when it cannot.

(15) Fixed User Defined Nodes failing with "Failed to create class of type" when another C Sharp Compiler with the same name, such as the one in the Execution Analyzer add-in, had loaded first. A node now uses the compiler that defines its User Defined Node.Executable Class, then the one closest to it in the tree.

(16) Fixed messages occasionally being lost while a sequence or scan was running, which could leave a 1D Scan running after its scan axis reached the end of the line.

(17) Fixed stash tasks such as Workspaces Tools.Stash Backup(), Managers View.Compare To Stash() and FPObject Stash.Open And Stash Workspace(), and the MCP tools that load a stash, reporting a generic failure instead of the reason. A Component naming something the workspace file does not have now fails with a list of the components the file has, and a numbered component is found with or without a space before its number.



Overview

This document contains a downloadable Windows installer for InspectionWare as well as the release notes covering the current version.

Software requirements

  • Operating system: Windows 10 or 11. The latest Windows updates must be installed.
  • InspectionWare 12 ships as a 64-bit application. 32-bit builds are produced only occasionally.
  • .NET Framework 4.8 or later is required. If it is not already installed, click here to download and install it.

Hardware requirements
  • CPU: A processor supporting the AVX2 instruction set is required. This includes 2013-or-later Intel processors and 2015-or-later AMD processors. (List of supported CPUs.) InspectionWare will not install or run on a CPU without AVX2.
  • GPU (optional, for accelerated processing): InspectionWare provides two GPU acceleration backends:
    • DirectX — any GPU supporting DirectX 11 (feature level 11_0) or later, from AMD, Intel, or NVIDIA. A CPU-based software fallback (WARP) is also available when no compatible GPU is present.
    • CUDA — an NVIDIA GPU with architecture ≥ Turing (e.g. RTX 2060, Quadro RTX, T4) and NVIDIA driver ≥ 576.02. NVIDIA GPUs older than Turing (e.g. Pascal / GTX 10-series) are not supported by the CUDA backend.

Additional resources

After downloading the installation files you may also want to review/download the following resources: Download and Installation Instructions
  1. Right-click on the file name in the "Downloads" section below and choose "Save Target As" or "Save..." to download the file to your computer.
  2. Locate the file you have just downloaded then run it to initiate the install process.



Access to downloads on this page is restricted.
Please provide the following:
( Required field)
E-mail:
Download Password:
The following file links will become active once the required information is submitted: