» Support » Downloads » Drivers
Installer for Olympus Focus PX SDK
Installer PxSDK_ETO0366-1.0R7T3
Note:

    The following drivers are provided as a courtesy to UTEX Scientific Instruments customers, and are therefore offered on an "as is" basis. UTEX does not maintain or support these drivers. If you are unsure of what driver to use, please consult the hardware manufacturer directly, or contact UTEX for further guidance.

Supported Instruments:

    Olympus Focus PX SDK version only

System Requirements:
    • InspectionWare 10.0.031 and later. InspectionWare 10.5.xx or later is recommended
    • Not compatible with Olympus Focus PC, Olympus TomoView, or Olympus NDT Bootp Server.
    • Installer must be run as an Administrator.
    • Network card settings should be set according to Olympus specification as follows:
Download Instructions:
    1. Please see the "Related Files" section below
    2. Ensure you download the correct version of SDK for the version of InspectionWare that you are using.
    3. Right-click on the file name and choose "Save Target as" or "Save..." to download the file to your computer.
    4. Right-click on the downloaded *.exe file, and select Run As Administrator to start the installation.
    5. 5. Copy the appropriate 32 bit or 64 bit DLLs from the install folder and paste them into the corresponding InspectionWare
Host PC Network Interface Requirements:

To optimize data transfer:

        • Execute the following netsh commands:
            • netsh int tcp set global chimney=enabled
            • netsh int tcp set global autotuninglevel=disabled
            • netsh int tcp set global congestionprovider=ctcp
            • netsh int tcp set heuristics disabled
        • Enable jumbo packets on network card to 9014 Bytes
Firewall

    Firewall must be correctly configured to allow traffic for the dedicated network connection and for FocusPC.exe You may need to disable firewall in order for Focus PX communications to work correctly.

DLLs Copy to InspectionWare


    Some of the installed dll's must be copied from their installation folder, into the corresponding InspectionWare folder. DLLs are available in both 32 bit and 64 bit. Use the files that are appropriate to your version of InspectionWare.

    For example, for a 64 bit installation of InspectionWare 10


      Copy the following files:

        1. log4cplus.dll

        2. PxSdkConfiguration.dll


      from C:\OlympusNDT\PxSDK\PxSDKClient\Bin\x64


        to C:\InspectionWare10\Bin64


Access to downloads on this page is restricted.
Please provide the following:
( Required field)
E-mail:
Download Password:
The following file links will become active once the required information is submitted:
Related Files
Focus PX SDK Installation Help.pdf (533.9 kB)
Install_PxSDK_ETO0366-1.0R7T3.exe (77 MB)
Document Reference
Categories
Instruments
NDE Software
Olympus
InspectionWare 
Product Version/Model
IW 10.0, IW 10.5 
Document Number
DSEO-AQQPL92419
Published
08/30/2017 Rev: 1.0
  Print Email page Share