Release 1.0-R3.1 (March 22, 2023)
Fixes
- Fixed custom law file load displaying random peaks in AScan
- Fixed loading custom law file would not clear the previous beam gains
Drivers
- FocusPX - OpenView Version 1.1.72.2 or greater (Download here, Password: OlympusOpenView)
- Galil Motion Controller - gclib (Download here)
Release 1.0-R3(March 30, 2022)
Features
- Added Min/Max peak selection to TVG gate
- Added Min/Max peak selection to PA Sensitivity gate
- Added dual thresholding mode to all gates
Fixes
- Fixed Probe Check page showing a blank AScan/BScan
- Improved accuracy of auto TVG gain calculation
Drivers
- FocusPX - OpenView Version 1.1.72.2 or greater (Download here, Password: OlympusOpenView)
- Galil Motion Controller - gclib (Download here)
Release 1.0-R2.5 (February 23, 2022)
Fixes
- Fixed issue where AScan would freeze on scan start
Drivers
- FocusPX - OpenView Version 1.1.72.2 or greater (Download here, Password: OlympusOpenView)
- Galil Motion Controller - gclib (Download here)
Release 1.0-R2.4 (February 1, 2022)
Changes
- Following UI elements are disabled when a scan is in progress
- Settings panel to the left
- TVG curve dragging on the plot
- Palette editor window
- Encoder/Motion dropdown menu
Drivers
- FocusPX - OpenView Version 1.1.72.2 or greater (Download here, Password: OlympusOpenView)
- Galil Motion Controller - gclib (Download here)
Release 1.0-R2.3 (October 18, 2021)
Fixes
- Fixed issue with beam selection cursor not changing the displayed Ascan on the PA Sensitivity page
Drivers
- FocusPX - OpenView Version 1.1.72.2 or greater (Download here, Password: OlympusOpenView)
- Galil Motion Controller - gclib (Download here)
Release 1.0-R2.2 (June 16, 2021)
Features
- Added support for daisy chained FocusPX instruments
Drivers
- FocusPX - OpenView Version 1.1.70.1 or greater (Download here, Password: OlympusOpenView)
- Galil Motion Controller - gclib (Download here)
Release 1.0-R2.1 (May 7, 2021)
Minor release with bug fixes
Changes
- Gain control in header bar is disabled when an inspection is in progress
- Auto Connect option is available on the Galil device
Fixes
- Fixed UI glitches on the Axis Homing and Landmarks pages
- Fixed issue with MicroPulse hardware gates where sometimes all AScans would be transferred
- Fixed UI issues on the Simulated Motion axis page
- Auxiliary Encoder could not be created
Drivers
- FocusPX - OpenView Version 1.1.70.1 or greater (Download here, Password: OlympusOpenView)
- Galil Motion Controller - gclib (Download here)
Release 1.0-R2 (Apr 16, 2021)
Features
- Support for MicroPulse Hardware Gates (Conventional only for now)
- Remote API added new general tasks:
- Get Preference
- Set Preference
Fixes
- Conventional channels would use Shear velocity with Inspection Mode set to Longitudinal
- Fixed issue where aux encoder swap button would disappear
- Fixed issue where all collected AScan/BScan plots would randomly change to the same plot
- Fixed issue where collected AScans axis will be in us instead of mm/in
Drivers
- FocusPX - OpenView Version 1.1.70.1 or greater (Download here, Password: OlympusOpenView)
- Galil Motion Controller - gclib (Download here)
Release 1.0-R1 (Feb 24, 2021)
Features
- Remote API now allows streaming of collected 1D data sets to clients
- Remote API added new motion tasks:
- Reset Encoder
- Get Axis Position
- Set Axis Position
- Axis Go To
- Axis Jog
- Axis Run
- Stop Axis
- Stop All Axes
Changes
- Scanner Landmarks page UI has been simplified
- Axis Homing page UI has been simplified
Fixes
- Changing channels on Data Collection page with automatic display building would no change the current AScan.
- Using the Import Setup option would change the name of the current open setup file.
- Transducer Part and Serial Numbers not presnt in the Data Header
- Incorrect difference reported between Primary and Secondary cursors on 8bit data
Drivers
- FocusPX - OpenView Version 1.1.70.1 or greater (Download here, Password: OlympusOpenView)
- Galil Motion Controller - gclib (Download here)
Release 1.0-RC8 (Dec 15, 2020)
Features
- Encoder calibration for encoders can be changed on Data Collection page (only available when Load from Setup
option is enabled on the specific axis in Motors & Encoders)
Fixes
- Fixed wrong checksum being generated for data generated in JSON format
- Focus Length units when creating Focal Laws follows application units now
- Beam selector on sweeps would not show current beam number
- Beam selector would not work on Calibration pages
Drivers
- FocusPX - OpenView Version 1.1.67.3 or greater (Download here, Password: OlympusOpenView)
- Galil Motion Controller - gclib (Download here)
Release 1.0-RC7 (Oct 10, 2020)
Features
- New bug reporting tool in Help > Bug Report to generate a bug report package that can be emailed to Utex.
- IW Scan download page can be reached directly using Help > Check For Updates
- Remote controllers can now request current position of cursor on scanned data
Changes
- "Include In Setup File" setting on motion axes has been replaced with "Load From Setup File".
The former preference will not be converted, user must re-select the appropriate setting. It is also
recommended to resave any setup file in use.*
- Cursors on cscans now display their position with 3 decimal places of precision.
Fixes
- Fixed OpenView synchro echo mode offset from zero in some cases
- OpenView devices have better connection errors
- Fixed beam number selector disappearing sometimes
- Fixed encoder preset units always being in mm for 1D and 2D recorders
Drivers
- FocusPX - OpenView Version 1.1.66.10 or greater (Download here, Password: OlympusOpenView)
- Galil Motion Controller - gclib (Download here)
Release 1.0-RC6 (Sept 11, 2020)
Features
- Added the ability to reorder ProbeSets and Channels.*
- New unified palette editor for all IW Suite applications.
- Current setup and data file names are shown in the title bar instead of only setup file name.
- Added a display preference to launch the application with navigation bar collapsed or expanded.
- Added ability to print the entire histogram window to PDF.
Fixes
- Tooltips on gates are now converted to inches
- Tooltips on tvg points are now converted to inches
- Expanding list of display sources now display a scrollbar when list is longer than window size
- Removed exit popup when right clicking anywhere in the UI
- Better handling of units when loading older machine configurations
- Scan freezing when the palette is changed on a CScan.
- Fixed annotations not being selectable on some display plots.
- Removed being able to drop annotations in histogram window.
Drivers
- FocusPX - OpenView Version 1.1.64.3 or greater (Download here, Password: OlympusOpenView)
- Galil Motion Controller - gclib (Download here)
*Note: Features or Fixes marked in orange may affect operation of the application at a fundamental level.